Gas Fire Extinguishing System and Mechanical Integration

Clean gas or inert gas extinguishing in electrical room, server room and sensitive areas, extinguishing agent calculation, nozzle and sealing.

Technical System Scope

Design, calculation and application details for Gas Extinguishing

The evaluation of gas extinguishing starts from the use of the room to be protected: the room volume, openings, ventilation arrangement, possible human presence and the existing detection system are examined together. The agent, deployment and evacuation scenario are defined based on information specific to this location.

01 / SYSTEM

Risk and volume analysis

The net volume of the space, suspended ceiling, raised floor, equipment, user presence and electrical risks are determined separately.

02 / SYSTEM

Gaseous agent evaluation

Clean gas or inert gas options are compared against equipment compatibility, design density, user safety, and current manufacturer/standard requirements.

03 / SYSTEM

Cylinder and piping

Cylinder placement, collector, discharge time, pressure relief, nozzle diameters and distribution pipes are determined by the manufacturer-approved calculation method.

04 / SYSTEM

Sealing in place

In door fan tests, leakage areas, gas retention time and openings to be limited are evaluated.

05 / SYSTEM

Sensing integration

Smoke/heat detection scenario, dual sensor, manual evacuation, delay, warning, air conditioning stop and cancellation procedures are coordinated.

06 / SYSTEM

Test and evacuation safety

Safe evacuation of people, automation simulation, cylinder control and post-evacuation safety of the space are documented.

Project Documents

Calculation, equipment and scope of delivery

In gas extinguishing project work, current dimensions of the space to be protected, door and vent positions, cylinder placement area, nozzle points, detection-control interfaces and discharge safety are converted into technical drawings and calculation inputs.

  • Risk and volume analysis
  • Gaseous agent evaluation
  • Cylinder and piping
  • Sealing in place
  • Sensing integration
  • Test and evacuation safety

Depending on the type of project, quantity surveying, technical specifications, test procedure and as-built drawings are also included in the scope of work.

Standardization and Security

Technical conditions and important notices

TS EN 15004, relevant agent conditions, user exposure and manufacturer acceptance procedures are taken as basis. This system is for fire extinguishing agents; It is not a fuel gas installation.

The current BYKHY, relevant product and system standards, manufacturer conformity certificates and authorized administration/fire department opinions are verified at the beginning of the design. Fixed flow/pressure/capacity values ​​are not declared without project data.

Technical Project Request →

Discovery inputs and engineering deliverables

In Gas Fire Extinguishing work, the following information can be shared at the first meeting. Field detection or additional calculation requirements for missing data are determined separately. Preparation of documents does not automatically guarantee acceptance by the relevant institution or a particular test result.

Scope table for Gas Fire Extinguishing
Startup entryOutput to be defined in the proposal
Space usage, volume and opening informationScope of agent and system selection
Current agent and equipment documentationMechanical placement and discipline coordination
Detection and security scenario inputsList of documents required for testing and acceptance

Frequently asked questions

How to prepare a quote for Gas Fire Extinguishing?

The facility's district, usage type and requested service, as well as location usage, volume and opening information are shared. Account, project, application and test items are separated in the written scope.

What to do if the doors and grilles in the gas extinguishing room change?

The ventilation scenario is re-examined with changes made to the room's doors, vents or cable passages. The effects of these changes on sealing, agent distribution, detection and safe discharge patterns are evaluated separately.

What documents are submitted?

The scope of agent and system selection, mechanical layout and discipline coordination and other documents included in the scope of work are delivered. The file format and revision scope are determined at the outset.

Is the gaseous extinguishing agent selected the same for each room?

No. Since the space volume, sealing, agent selection and human safety conditions are different in gas extinguishing, project-specific data of the space and system components are determined first.

Are implementation and control the same scope?

Project planning, assembly, field inspection and testing tasks are defined separately. The proposal states which party is responsible for which work.

From which regions do you receive requests for exploration?

Requests from Çorlu, Ergene, Kapaklı and Tekirdağ are evaluated from our Çerkezköy center. The time and conditions of the field visit are decided separately.

Discovery and technical proposal request

Share the facility location, current project status and desired service for Gas Fire Extinguishing. Let's clarify the scope of discovery, calculation, application and delivery together.